Herunterladen Inhalt Inhalt Diese Seite drucken

Before Use - Hilti AG 125-A36 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für AG 125-A36:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Total vibration (vector sum of three directions), measured in accordance with EN 60745
Other applications, such as cutting, may produce vibration values that deviate from the given values.
Surface grinding with the
vibration-absorbing side handle (a
Uncertainty (K)

5 Before use

5.1 Inserting the battery
CAUTION
Risk of injury. Due to the angle grinder starting unintentionally.
▶ Before fitting the battery, check that the angle grinder is switched off and that the safety lock is
activated.
CAUTION
Electrical hazard. Dirty contacts may cause a short circuit.
▶ Before inserting the battery, check to ensure that the battery terminals and the contacts in the
angle grinder are free from foreign objects.
CAUTION
Risk of injury. If the battery is not fitted correctly it may drop out and fall.
▶ Check that the battery is securely seated in the tool so that it cannot drop out and fall, thereby
presenting a hazard to other persons.
▶ Fit the battery and check that the battery is securely seated in the power tool.
5.2 Removing the battery
▶ Remove the battery.
5.3 Fitting the side handle
▶ Screw the side handle into one of the threaded bushings provided.
5.4 Fitting or removing the guard
CAUTION
Risk of injury. The accessory tool may be hot or have sharp edges.
▶ Wear protective gloves when fitting, removing or adjusting the accessory tool or other parts and
when troubleshooting.
▶ Observe the instructions for fitting the applicable guard.
5.4.1 Fitting the guard
7
Note
The guard is equipped with locating lugs that ensure only guards of a type suitable for use with the
power tool can be fitted. The locating lugs of the guard fit into the guard mount on the power tool.
1. Fit the guard onto the drive spindle collar so that the two triangular marks on the guard and on the power
tool are in alignment.
2. Press the guard onto the drive spindle collar.
3. Press the guard release button.
4. Rotate the guard until it engages and the guard release button jumps back into its original position.
26
Printed: 14.09.2015 | Doc-Nr: PUB / 5246577 / 000 / 00
AG 125­A36
3.2 m/s²
)
h,AG
1.5 m/s²
5
6
AG 150­A36
4.6 m/s²
1.5 m/s²

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ag 150-a36

Inhaltsverzeichnis