Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 68
Parts and their function
 MONITOR1, 2 connectors
The video signals of the cameras selected by the pan/tilt
control panel (AW-RP400) or the remote operation panel
(AW-CB400) which is connected to the AW-RP400 are
output from these connectors.
The output signals are cable-compensated signals of the
same type as the input signals. For instance, if a channel
to which composite signals have been input is selected,
these composite signals will be cable-compensated and
output.
 Y/VIDEO IN connectors [1 to 5]
The analogue video signals are input to these connectors.
They are terminated internally by a 75-ohm resistance.
Either Y (component signals or Y of the Y/C signals with
sync) or VIDEO (composite) signals are supplied.
 Pr/C IN connectors [1 to 5]
The analogue video signals are input to these connectors.
They are terminated internally by a 75-ohm resistance.
Either Pr (R-Y among the component signals) or C (C of
the Y/C signals) signals are supplied.
 Pb IN connectors [1 to 5]
The analogue video signals are input to these connectors.
They are terminated internally by a 75-ohm resistance.
The Pb (B-Y among the component signals) signals are
supplied.
 Y/VIDEO OUT connectors [1 to 5]
The analogue video signals are output from these
connectors. Cable-compensated Y or VIDEO (composite)
signals that are in accordance with the input signals are
output. Y signals are output if component Y signals have
been input to the Y/VIDEO IN connectors [1 to 5], and
composite signals are output if composite signals have
been input.
 Pr/C OUT connectors [1 to 5]
The analogue video signals are output from these
connectors. Cable-compensated Pr or C signals that are
in accordance with the input signals are output.
Pr signals are output if Pr signals have been input to the
Pr/C IN connectors [1 to 5], and C signals are output if C
signals have been input.
 Pb OUT connectors [1 to 5]
The analogue video signals are output from these
connectors. Cable-compensated Pb signals are output if
Pb signals have been input to the Pb IN connectors
[1 to 5].
Cable Compensation Unit AW-RC400
 AC adapter storage space
The AC adapter can be stored here when the ambient
temperature in the location where the cable compensation
unit has been installed is under 30 °C.
Remove the 2 screws, and remove the storage space
cover. Stow the AC adapter (AW-PS301) in such a way
that the pull-out cable will not be stressed. Trouble will
occur in the AC adapter if the ambient temperature
exceeds 30 °C, in which case it should not be stored in
the space.

 Cable clamp

This is used to clamp the cable of the AC adapter
(AW-PS301) in place and prevent it from coming loose.
48 (E)

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Aw-rp400lAw-rc400lAw-rl400g

Inhaltsverzeichnis