Pan/Tilt Control Panel AW-RP400
Menu settings
OPTION SWITCH A to H settings
(NOT USE / DEF / WIP / HEATER/FAN / LAMP / OPTION / ND / EXT / AF)
The following functions can be allocated to OPTION buttons A to H. Different functions can be allocated for different pan-tilt
heads.
NOT USE:
DEF:
WIP:
HEATER/FAN: This controls the ON and OFF states of the heater/fan function when using a pan-tilt head system
LAMP:
OPTION:
ND:
EXT:
AF:
MEMORY LENGTH setting (60s/120s/300s/600s)
This menu item is used to set the tracing memory data recording time and the number of memories.
60s : 60 seconds M 10 memories
120s : 120 seconds M 5 memories
300s : 300 seconds M 2 memories
600s : 600 seconds M 1 memory
p When data has already been registered in a tracing memory, the setting for the recording time and number of memories
cannot be changed. To reset a setting, delete the registered data in the tracing memory first.
The button is disabled.
This controls the ON and OFF states of the defroster function when using a pan-tilt head system
equipped with this function.
Each time the button is pressed, ON is switched to OFF or vice versa.
When the defroster function is ON, the lamp of the button to which this function has been allocated is lit;
when it is OFF, the lamp is off.
This controls the ON and OFF states of the wiper function when using a pan-tilt head system equipped
with this function.
Each time the button is pressed, ON is switched to OFF or vice versa.
When the wiper function is ON, the lamp of the button to which this function has been allocated is lit;
when it is OFF, the lamp is off.
equipped with this function.
Each time the button is pressed, ON is switched to OFF or vice versa.
When the heater/fan function is ON, the lamp of the button to which this function has been allocated is lit;
when it is OFF, the lamp is off.
This controls the ON/OFF switching of the power from the AC outlet which is used for the AC adapter's
lamp when using an AC adapter for a pan-tilt head provided with a lamp control function.
Each time the button is pressed, ON is switched to OFF or vice versa.
When the lamp is ON, the button to which the function is allocated lights; when it is OFF, the button goes
off.
If the lamp fails at the ON setting, the button blinks.
This controls the short-circuit and open-circuit states of the AC adapter's OPTION CONTROL OUT
connector when using an AC adapter for a pan-tilt head system equipped with the OPTION switch
control function.
Each time the button is pressed, short circuit is switched to open circuit or vice versa.
When short-circuited, the lamp of the button to which this function has been allocated is lit; when
open-circuited, the lamp is off.
This controls the ON and OFF states of the ND filter when using a lens equipped with an ND filter.
Each time the button is pressed, ON is switched to OFF or vice versa.
When the ND filter is ON, the lamp of the button to which this function has been allocated is lit; when it is
OFF, the lamp is off.
This controls the ON and OFF states of the extender when using a lens equipped with an extender.
Each time the button is pressed, ON is switched to OFF or vice versa.
When the extender is ON, the lamp of the button to which this function has been allocated is lit; when it
is OFF, the lamp is off.
This controls the ON and OFF states of the auto focus function when using a lens equipped with this
function.
Each time the button is pressed, ON is switched to OFF or vice versa.
When the auto focus function is ON, the lamp of the button to which this function has been allocated is
lit; when it is OFF, the lamp is off.