Parts and their function
w Rear panel
"
" EXT CONT IN/OUT connectors
When an additional AW-RP400 is to be provided, connect
these connectors on the 2 AW-RP400 using a 10BASE-T
(equivalent to UTP category 5) straight cable.
Master
control panel
AW-RP400
EXT CONT
IN
10BASE-T straight cable
EXT CONT
OUT
# CAMERA CONTROL IN FROM RCB [P1] to [P5]
connectors
Connect the remote control boxes (WV-CB700A) to these
connectors.
The cameras installed on the pan-tilt heads
corresponding to the ports where the WV-CB700A boxes
have been connected can then be controlled.
When even one WV-CB700A box is connected, the
cameras cannot be controlled from the remote operation
panel (AW-CB400) even if the AW-CB400 is connected.
#
$
'
(
$ TALLY/INCOM connector
Connect this to the TALLY/INCOM connector on the video
switcher or other unit.
When the TALLY input connector is set to the GND level,
the TALLY lamp on the control panel or pan-tilt head
Slave
lights.
control panel
Do not apply a voltage in excess of 5 V to this connector.
AW-RP400
EXT CONT
IN
Pin layout as seen from the
back panel of AW-RP400
EXT CONT
Pin No.
OUT
1
2
3
4
5
6
7
8
Use the accessory plug (D-SUB 15-pin) to connect the
tally/INCOM signals to the system.
Connect a 4-wire INCOM system to the INCOM
connector.
When an additional control panel has been provided or
when the remote operation panel (AW-CB400) has been
connected, the tally or INCOM function of all the units will
take effect if tally or INCOM signals are connected to one
of the units.
34 (E)
Pan/Tilt Control Panel AW-RP400
%
&
)
*


Signal name
TALLY1
9
TALLY2
TALLY3
10
TALLY4
TALLY5
11
TALLY GND
– – –
12
– – –
– – –
13
– – –
MIC+
14
MIC–
INCOM GND
15
SP–
SP+