Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - CleanSpace EX Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für EX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 164
English
CleanSpace Respirators
Filters – For Particulates
Product Code
Description
PAF-0037
Particulate Filter P3 / TM3 P SL R High Capacity
Particulate Filter P3 – Replacement Pads for Combined Filters PAF-0046 and PAF-0047 – 3 Pk
PAF-0043
(Australia only)
Particulate Filter P3 – Replacement Pads for Combined Filters PAF-0046 and PAF-0047 – 8 Pk with
PAF-0053
Honeycomb Lid (Australia only)
Combined Filters – For Gases & Particulates
Product Code
Description
PAF-0038
Filter Adaptor - all large-case filters (PAF-0037, PAF-0046, PAF-0047, PAF-0050, PAF-0051)
PAF-0046
Combined Filter A1P3 (Australia)
PAF-0047
Combined Filter ABE1P3 (Australia)
PAF-0050
Combined Filter TM3 A1 P SL R (Europe)
PAF-0051
Combined Filter TM3 ABE1 P SL R (Europe)
Pre-Filters and Coveralls
Product Code
Description
PAF-0036
Particulate Pre-Filter (Standard)
PAF-0057
Particulate Pre-Filter (Large Case Filters)
PAF-0058
Particulate Pre-Filter and Coverall (Standard)
NOTIFIED BODIES
Respiratory Protection:
SAI Global Assurance Services Limited (2056)
PO Box 6236
Milton Keynes MK1 9E
IECEx
TestSafe Australia (IECEx TSA 13.0024X)
PO Box 592
Richmond NSW 2753 Australia

17. Specifications

Air Flow
Operating
Temperature Range
Operating Humidity
Range
Operating Altitude
Range
Charging
Temperature Range
Storage Conditions
Shelf Life (when
stored as specified)
Manufacturers minimum design flow: 120 litre/minute
Breath-responsive, with max inflow to mask 120 – 200 litre per minute, dependant on altitude,
filter and battery condition.
-10°C to 45°C. The motor will shut down if the temperature of the battery pack rises above
60°C or falls below -10°C
Zero to 90%, non-condensing
Approximately sea level to 1200m
0°C to 35°C
Below 0°C and above 35°C the battery may not accept charge
Short term storage under 30 days:
Out of direct sunlight, in a clean, dry environment (30% - 50% RH), -10°C to 35°C.
To maintain the integrity of the internal battery, the respirator must be stored under the
following conditions when it will not be used for longer than 1 month
Long term storage (> 30 days):
Out of direct sunlight, in a clean, dry environment (30% - 50% RH), 18°C to 28°C.
We recommend to charge the battery every 6 months if the device is not in use.
Particulate Filters: 3 years
ATEX
Intertek Testing & Certification Limited (ITS14ATEX27939X)
Cleeve Road, Leatherhead, Surrey, KT22 7SB
United Kingdom
30
USER INSTRUCTIONS

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

UltraPaf-0060Paf-0070

Inhaltsverzeichnis