7. Controls and Indicators

POWER BUTTON
This button is used to switch between the three (3) operating Modes: "On", "Standby" and "Off".
i) Standby Mode is when the green battery indicator lights are on, the motor is not running and there is no
airflow to the mask. The respirator will automatically switch to Standby Mode within ten (10) seconds of the
user taking off the respirator. If the CleanSpace Respirator is in Off Mode it will switch to Standby Mode
when the Power button is pressed.
ii) On Mode is when the respirator is being worn, the motor is running and there is air flow to the mask. The motor will start
(called On Mode) when the respirator detects a change in pressure in the mask triggered by your breathing. In On Mode you
should hear the motor running and feel the airflow on your face. You can also switch to On Mode (start the motor) from
Standby Mode by pressing the Power button once.
iii) Off Mode is when the green battery indicator lights are off and the motor is not running and there is no air flow to the
mask. The respirator automatically switches into Off Mode three (3) minutes after the respirator has been removed from the
user's face and the sensors detect that there is no breathing.
To conserve battery life, the CleanSpace Respirator is designed to automatically switch from On Mode to Standby then to Off
Mode when not being worn.
Important: CleanSpace Respirator switches into On Mode when the respirator is in Standby Mode and the wearer starts to
breathe. The respirator can only switch into On Mode from Standby Mode.
FLOW TEST BUTTON
This button is used to check that the respirator is able to deliver its minimum designed flow. Pressing it once,
when the CleanSpace Respirator is in Standby Mode (not ON Mode), starts the flow test which lasts about 5
seconds. See Section 9 for instructions on running the flow test.
BATTERY INDICATOR LIGHTS
CleanSpace Respirator is equipped with an indicator of battery charge. There are three (3) battery indicator
lights. With the charger plugged in and three green lights lit, the battery is fully charged and has minimum
four (4) hours of operating time. The respirator should be fully charged before use.
CleanSpace Respirator will function with one (1) or two (2) green battery lights illuminated. If two (2) battery indicator lights
are on, the respirator has between 25% and 75% charge and will typically operate for between 1 and 3 hours. If only one (1)
battery indicator light is on, the battery has less than 20% charge and we recommend that you charge the respirator before
use.
When the battery approaches a level at which it would not be able to supply the Manufacturer's Minimum Design Flow, an
alarm sounds (3 beeps, repeated once per second). All green battery lights are extinguished. If the low battery alarm sounds
you must leave the contaminated area immediately and recharge the battery.
Operating time is strongly affected by work rate, altitude, and other factors. The operating times quoted above are average
durations at moderate work rates at sea level. Actual operating times may vary widely from average durations.
FILTER WARNING ALARM
CleanSpace Respirator has a Filter Warning Alarm, which is triggered when the filter is blocked. If the Filter
Warning Alarm sounds (two beeps, repeated once per second) or the Filter Warning Alarm light comes on, you
must move out of the contaminated area, and change the filter.