CleanSpace Respirators
swap to a neck support suited to a larger head size – see above. Then start the donning process again.
Finally, reach behind your head and find
the harness rear strap. Locate the hook
on the bottom end of the strap. Snap the
hook onto the hoop on the filter cover of
CleanSpace Respirator so that the rear
strap supports the weight of the
respirator.
Adjust the respirator vertical position
Adjust the rear strap to set the height of
the respirator. CleanSpace Respirator
should sit roughly level (as shown
below). If your job involves looking up a
lot (for instance sanding a ceiling) you
may prefer to tighten the strap more to
raise the respirator and give yourself
more space for head movement.
You can set how close CleanSpace
Respirator sits to your neck by adjusting
the bellows on either side of the
respirator. If your job involves a lot of
rapid movement (for instance running up
stairs) you may wish the respirator to sit
snugly against your neck. If you will be
looking up a lot, you may find it more
comfortable with the respirator set well
back from your neck.
To move the respirator forward: steady
the mask with one hand and press on the
back of the respirator with the other.
You will hear clicking as the adjust
mechanism moves to the new position.
Be careful to adjust each side by the
same amount. To move the respirator
backwards, press the adjust buttons on
each side and if necessary pull
backwards on the respirator.

10. Entering and Exiting the Contaminated Area

Prior to entering the contaminated area, complete the inspections and checks listed in these user instructions.
1. Ensure Seal Check has been done and motor is responding to your breathing
2. Check that none of the alarms are sounding.
3. Remember that if your workplace is very noisy you may not be able to hear the device alarms. In this case you must
follow the special precautions set out in Section 11.
4. Enter the work area
5. Do not remove the respirator until you have left the contaminated area, unless you have pressing health reasons to do
so (for instance you are experiencing dizziness and believe removing the respirator while you leave the contaminated
area may help).
21