The breakaway PC board of the new
1
RECERBO must also be removed and
returned with the faulty RECERBO to
Fronius.
NOTE! If the breakaway PC board
is forgotten or not inserted correct-
ly, the inverter will show a status
code (482) on the display.
Insert the previously separated brea-
2
kaway PC board (4) on the internal
side of the new RECERBO.
Mount the RECERBO holder (3) on the
3
new RECERBO
- thread the wire up
- press down.
NOTE! All guide pins and bolts
must be engaged.
Insert the new RECERBO assembly
4
The locks (2) on the RECERBO holder
5
must be fully engaged in the housing
frame
Insert the external fan cable in the cab-
6
ling (1)
Insert the Datamanager card, close the
7
inverter and insert into the wall bracket
(see "Replacing the Datamanager
Card" and "Opening and Closing De-
vice" sections)