Herunterladen Inhalt Inhalt Diese Seite drucken

Protection Systems; Description Of Blockages - DAB ESYBOX DIVER Serie Installations- Und Wartungsanleitungen

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 47
7.34.3
Sleep Mode Duration
Sets the duration of the function (min 5'; max 24h).
7.34.4
Sleep Mode remaining time
Countdown of Sleep Mode operating time. When it reaches 0 the function is no longer active and the pump returns to pressurise the system at
setpoint pressure.
7.35
RF: Resetting errors
Deletes Fault and Warning history.
7.36
Error Display
Display of the errors that have occurred during system operation.
7.37
Manual reset of error conditions
Forces the deletion of the present error.
7.38
Firmware release
7.39
Firmware update
7.40
Factory settings
Restores the factory settings of the parameters.
8

PROTECTION SYSTEMS

The device is equipped with protection systems to preserve the pump, the motor, the supply line and the inverter. If one or more
protections trip, the one with the highest priority is immediately notified on the display. Depend- ing on the type of error the motor may stop,
but when normal conditions are restored the error status may be cancelled immediately or only after a certain time, following an automatic
reset.
In the event of a blockage due to an error, you can attempt to exit the error conditions manually by sending the appropriate command.
If the error condition remains, you must take steps to eliminate the cause of the fault.
In the event of blocking due to one of the internal errors E18, E19, E20, E21 it is necessary to wait 15 minutes with the machine
powered until the blocked status is automatically reset.
8.1

Description of blockages

8.1.1
"BL" Anti Dry-Run (Protection against dry running)
In the case of dry running the pump is stopped automatically after the time TB.
After having restored the correct flow of water you can try to leave the protective block manually by sending the Error Reset
command. If the alarm status remains, or if the user does not intervene by restoring the flow of water and resetting the pump, the automatic
restart will try to restart the pump.
Indication
Cutout due to pump overheating
PH
Blockage due to dry operation
BL
Blockage due to reading error on the delivery pressure sensor
BP1
Blockage due to supply voltage outside specifications
PB
OT
Blockage due to overheating of the power stages
OC
Blockage due to motor overload
NC
Blockage due to motor disconnected
Ei
Blockage due to i-th internal error
Vi
Blockage due to i-th internal voltage out of tolerance
EY
Block for cyclicality abnormal detected on the system
Table 4 Indication of blockages
ENGLISH
Blockage conditions
Description
24

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis