Herunterladen Inhalt Inhalt Diese Seite drucken

Protection Systems - DAB e.sybox mini Bedienungs Und Wartungsanweisungen

Inhaltsverzeichnis

Werbung

GB
ENGLISH
5.7- Setting low pressure detection on suction (typically used in
boosting systems connected to the water mains)
The low pressure detecting function generates the blocking of the system
after the time T1 (see 5.5.6 - T1: Low pressure delay).
When this function is active the symbol F4 is shown on the main page.
Tripping of this function causes the pump to cut out; it may be reset auto-
matically or manually. The automatic reset requires that, to leave the error
condition F4, the pressure must return to a value higher than the threshold
PK for at least 2 sec.
To reset the cut-out in manual mode, press and then release the "+" and
"-" keys simultaneously
5.8 - RF: Fault and warning reset
Holding down the + and – keys together for at least 2 seconds deletes the
history of faults and warnings. The number of faults present in the log is
indicated under the symbol RF (max 64).
The log can be viewed from the MONITOR menu on page FF.
5.8.1 - PW: Change password
The device has a password-enabled protection system. If a password is
set, the parameters of the device will be accessible and visible but it will
not be possible to change them.
When the password (PW) is "0" all the parameters are unlocked and can
be edited.
When a password is used (value of PW different from 0) all modifications
are blocked and "XXXX" is displayed on the page PW.
If the password is set it allows to navigate through all the pages, but at
any attempt to edit a parameter a pop-up appears, asking you to type in
the password. When the correct password is typed in the parameters are
unlocked and can be edited for 10' after the last key is pressed.
If you want to cancel the password timer, just go to page PW and hold
down + and – together for 2".
When the correct password is typed in a padlock is shown opening, while
if the wrong password is given a flashing padlock appears.
After resetting the factory values the password is set back at "0".
61
Each change of the password takes effect when Mode or Set is pressed
and each subsequent change of a parameter implies typing in the new
password again (e.g. the installer makes all the settings with the default
PW value = 0 and lastly sets the PW so as to be sure that the machine is
already protected without any further action).
If the password is lost there are 2 possibilities for editing the parameters
of the device:
• Make a note of the values of all the parameters, reset the device with
the factory values, see paragraph 7.3. The reset operation cancels all
the parameters of the device, including the password.
• Make a note of the number present on the password page, send a
mail with this number to your service centre, in a few days you will be
sent the password to unlock the device.

6 - PROTECTION SYSTEMS

The device is equipped with protection systems to preserve the pump, the
motor, the supply line and the inverter. If one or more protections trip, the
one with the highest priority is immediately notified on the display. Depend-
ing on the type of error the motor may stop, but when normal conditions
are restored the error status may be cancelled immediately or only after a
certain time, following an automatic reset.
In the case of blockage due to water lack (BL), blockage due to motor over-
load (OC), blockage due to direct short circuit between the motor phases
(SC), you can try to exit the error conditions manually by simultaneously
pressing and releasing the + and – keys. If the error condition remains, you
must take steps to eliminate the cause of the fault.
In the event of blocking due to one of the internal errors E18, E19, E20,
E21 it is necessary to wait 15 minutes with the machine powered until the
blocked status is automatically reset.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis