Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Checks - Pre-Starting; Inspection Prior To Operation; Operation - Ingersoll-Rand BXR-100H Betriebs- Und Wartungsanweisungen

Reversierbarer plattenverdichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 55
SAFETY CHECKS – PRE-STARTING
Before starting each day, in addition to the 10 hour daily routine
maintenance, check or inspect the following items to ensure
trouble free performance.
1. Check fluid lines, hoses, fittings, filler openings, drain plugs,
pressure cap, muffler, safety shrouds and the area
underneath the unit for signs of leakage or damage. Fix any
leaks and correct any damage before operating.
2. Inspect the entire unit for damaged or missing parts and
repair or replace them as needed.
3. Check the fuel level. If necessary, fill the fuel tank with the
proper fuel.
4. Check all fastening hardware to ensure it is adequately
tightened and that none is missing or broken.
5. Do not operate faulty equipment.
6. Be observant of people and obstructions within the work
area.
Please read "INSTRUCTIONS FOR USE" for HONDA engine
GX160 and this instruction manual for correct use and care.
Please check if the unit is correctly maintained in good
operating conditions.

INSPECTION PRIOR TO OPERATION

Check Engine Oil
Before checking or refilling engine oil, be sure the compactor is
located on a stable level surface.
Do not thread the gauge into oil filler to check oil level. If the oil
level is below the lower level line on the dipstick, refill with the
proper oil to the upper level (to the neck of oil filler). See
SECTION – MAINTENANCE, "100 HOUR OR MONTHLY
MAINTENANCE".
Check Engine for Fuel
WARNING
Do not refuel while smoking near an open flame or other
potential hazards.
Cleaning Air Cleaner
Check Air Cleaner to be sure it is clean and not contaminated.
If cleaning is required perform the following steps:
Remove the outer urethane foam and inner element.
Wash the element in kerosene or diesel fuel.
Saturate it in a mixture of 3 parts kerosene or diesel fuel and
1 part engine oil.
Shake off excessive oil and reinstall.
Wash the air cleaner case using kerosene.
After cleaning it up, apply engine oil on the inner part of the
case.
If the air cleaner element is seriously contaminated engine
start up may fail or poor output and malfunctions of the
engine may result.
Check each part for lose or broken Bolts and Nuts
Tighten loose bolts and nuts, if any. Check each part for fuel or
oil leak. Replace broken or damaged parts, if any, with new
ones.

OPERATION

Release the operating handle by pulling upward on the handle
pin ( , [Figure 1]) and move the operating handle down to the
operating position.
Figure 1
6-EN
CAUTION
BXR-100H Reversible Plate Compactors
Operation & Maintenance Manual

Werbung

Inhaltsverzeichnis
loading