5.10.1.

Removal

Put the power generator out of service.
Switch the automatic circuit-breakers off.
Secure the power generator against being switched on.
If necessary, attach warning notices.
Remove the battery compartment cover (20-15). To do this, undo the 8 fastening screws and
take the cover off.
Remove the battery cover. By loosening the 2 nuts of the tension rods.
Disconnect the minus cable by undoing the respective connection terminal on the battery.
Disconnect the plus cable by undoing the respective connection terminal on the battery.
Remove the battery.
Secure the power generator against being switched on or insulate the connection terminals on
the battery cables.
5.10.2.

Installation

The sequence of operations for installation is the reverse of those for removal.
Clean the surface of the battery using a clean cloth.
Lightly grease the poles of the battery with battery grease or Vaseline.
Screw the connection terminals to the battery poles.
Make sure everything is securely seated.