Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Before Starting The Equipment; Attachment And Operation - Scheppach FS 3600 Originalanleitung

Fliesenschneidmaschine
Vorschau ausblenden Andere Handbücher für FS 3600:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6. Technical data

1560 x 440 x 1140mm
Dimensions L x W x H
Cutting table
Ø200 x Ø25,4 x 1,6 mm
Diamond cutting
disc Ø
Water filling quantity
Weight
Section data
Max. cutting length
Max. diagonal cutting
length
Max 90° cutting
height
Max. 45° cutting
height
Drive
Motor
Power intake
Motor speed
Insulating material
class
Protection type
Technical changes reserved!
NOISE CHARACTERISTIC VALUES
Noise at the workplace can exceed 85 dB (A). In this
case, noise protection measures are necessary for
the user (wear hearing protection!).
NOISE OUTPUT IN dB
sound power level of LWA = 86 dB (A) uncertainly 3
dB (A) Noise pressure level LPA = 72 dB (A) uncer-
tainly 3 dB (A) according to DIN EN ISO 3744; EN
ISO 11201

7. Before starting the equipment

Warning!
Always pull the power plug before making ad-
justments to the equipment.
Before you connect the equipment to the mains sup-
ply make sure that the data on the rating plate are
identical to the mains data.
• The machine must be stable, i.e. bolted down on a
standard workbench, base frame or similar.
• Prior to commissioning, all covers and safety de-
vices must be mounted correctly.
• The cutting wheel must be able to run freely.
• Get to know your machine. Familiarize yourself with
its use and its restrictions, but also with the specific
potential risks.
• Check the machine carefully for damages to en-
sure that it is able to achieve the intended output.
In case of doubt, please replace the concerned
component.
• Ensure that the switch is on Off, before inserting
the power plug into the mains socket.
• Ensure that the machine is cleaned and lubricated
properly.
• Before start-up, check the machine for damaged
parts and find out whether these parts are work-
ing properly and performing their defined function.
400 x 1290 mm
30,0 l
50 kg
920 mm
650 x 650 mm
36 mm
29 mm
230 V/50 Hz
900 W
3000 1/min
F
IP54
• Check the alignment of all moving parts, all bro-
ken or fastening parts, and all other conditions that
can affect smooth operation. Each damaged part
should be repaired or replaced by a technician im-
mediately.
• Do not use the machine if a switch cannot be acti-
vated/deactivated correctly.
Start-up of the leakage current circuit-breaker:
• The function should be checked before each start-
up and at regular Intervals (min. once every week).
• If the leakage current circuit-breaker does
not switch off properly during this test, the-
re is no personal protection! The device must
therefore be switched off immediately!
• In case of damages caused by the non-observa-
tion of this operating instructions manual, all war-
ranty claims will become null and void. We do not
accept any liability for consequential damages.
• Check the product for damage before each use! If
you detect a damage, do not connect the product
to the mains power supply!
• After actuating the orange Reset button, the device
is ready for operation. Before operation, please
test the triggering with the help of the Test button
(as described in "Operation").
• Insert the leakage current circuit-breaker into the
socket.
• Press the orange Reset button.
• A red symbol is displayed in the window indicating
operational readiness.
• Press the red Test button. This action simulates a
leakage current.
• If the machine is working properly, the circuit-brea-
ker will disconnect the load from the mains. This
is displayed in the window through the disappea-
rance of the red symbol.
• Protection of man and animal is effective only if the
machine works properly.
• The Reset button must be pressed a second time
for operation.
• The load can now be inserted.
8. Assembly
Assembly Fig. (3-5)
For packaging purposes, your machine
is not fully assembled.
Remove the machine from the packaging and place
1.
carefully to one side on the ground.
Unscrew the star knob screw (a) and fold the sup-
2.
porting feet down. Re-tighten the star knob screw
(Fig. 3)
3.
Place the machine on the feet.
Install the handle onto the motor housing using 2
4.
hexagon screws (b) (Fig. 4).
Secure the cooling water pump (13) into the pre-
5.
scribed position in the water pan (4)
6.
Fill the water pan until the water pump is completely
covered with water. Ensure that the discharge is
sealed securely.
GB
19

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

5806702984

Inhaltsverzeichnis