Fault
Ice forms in the inflow hose
to the ice maker.
Water runs from the
appliance.
pp
The water pressure is less
than usual.
The discharged water is not
g
cold.
The water appears cloudy.
Particles float in the water
or ice cubes.
60
Possible cause
Low water pressure.
Shut off tap incorrectly opened.
Temperature in the freezer space
is too high.
The water connection hose is not
properly sealed.
Incorrect shut off tap installed.
Low water pressure.
Shut off tap incorrectly opened.
Incorrect shut off tap installed.
Water supply has kinks.
The water filter is bunged up
or used.
The appliance is newly set up.
The water in the tank is exposed.
The water has stood for a long
period in the pipes outside of the
tank and has adapted to the room
temperature.
There is air or air bubbles in the
water.
The first water which runs through
the filter can rinse carbon dust out
of the filter.
If water freezes and thaws again,
particles are formed by mineral
deposits.
Remedial action
The water pressure must be between 1.72 bar
and 8.25 bar so that the appliance works
properly.
Open shut off tap fully.
Temperature in the freezer space should
lie between -17 and -18 °C, adjust where
necessary.
Replace the hose with a manufacturer's
original part.
Incorrect taps can cause low water pressure
and damage to the appliance.
The water pressure must be between 1.72 bar
and 8.25 bar so that the appliance works
properly.
Open shut off tap fully and check for leaks.
Check the minimum through flow.
Incorrect taps can cause low water pressure
and damage to the appliance.
Turn off the water supply at the shut off tap.
Smooth out the kinks, exchange where
necessary.
Changing the water filter
The water in the tank needs approx.12 hours
to cool down.
Throw the first glass of water away.
This is normal when using the dispenser for
the first time. It disappears after a short time.
The particles are not harmful! These particles
disappear after a short period.
The particles are not harmful! In the water
supply this is a natural occurrence.
pp