Fault
The ice maker does not make
enough ice or the ice is
g
deformed.
The ice maker does not make The ice maker is switched off.
any ice.
Condensation forms on the
discharge unit of the dis
penser.
Filter exchange message
appears in the display.
pp
p y
The illumination on the
dispenser unit does not work. The permanent light function is
Possible cause
The appliance or ice maker has
only just been switched on.
A lot of ice has been taken.
Low water pressure.
The water filter is bunged up
or used.
The appliance is not supplied with
water.
Water supply has kinks.
Low water pressure.
Temperature in the freezer space
is too high.
Ice cube container is not properly
inserted.
Incorrect shut off tap installed.
The ice maker is switched off.
The condensation heating is
deactivated.
Water filter cartridge must be
exchanged.
After exchanging the filter the filter
exchange display is not reset.
The bulb is defective.
deactivated.
Remedial action
Approx. 24 hours is needed until ice
production starts.
Approx. 24 hours is needed until the ice cube
container is filled again.
The water pressure must be between 1.72 bar
and 8.25 bar so that the appliance works
properly.
Changing the water filter
Switch the ice maker on at the control panel.
Contact the installer or the water supply
company.
Turn off the water supply at the shut off tap.
Smooth out the kinks, exchange where
necessary.
The water pressure must be between 1.72 bar
and 8.25 bar so that the appliance works
properly.
Temperature in the freezer space should
lie between -17 and -18 °C, adjust where
necessary.
Check the position, re insert where necessary.
Incorrect taps can cause low water pressure
and damage to the appliance.
To switch the condensation heating on:
-
Switch on the ice maker.
-
Press the lock button and the agitation
button simultaneously and keep pressed
for 3 seconds. The water button and ice
cube button flash twice.
The ice maker is switched off, but the
condensation heating function keeps working.
To switch the condensation heating off:
-
Press the lock button and the agitation
button simultaneously and keep pressed
for 3 seconds. The water button and ice
cube button flash once.
Exchange filter cartridge. If no new filter
is available, insert bypass cap.
Reset filter exchange display.
Replace bulb (see "Changing light bulbs").
Press the light button in order to switch the
permanent light function on.
59