Installation

Installation location

Install the appliance in a dry, well ventilated room. The
installation location should neither be exposed to direct
sunlight nor near a heat source, e.g. a cooker, radiator,
etc. If installation next to a heat source is unavoidable,
use a suitable insulating plate or observe the following
minimum distances to a heat source:
-
3 cm to an electric cooker.
-
30 cm to an oil or solid fuel cooker.
The floor on which the appliance is to be installed must
be rigid. If required, reinforce the floor. To ensure that the
ice maker functions correctly, the appliance must be
upright.
Observe ambient temperature and ventilation
The atmosphere grade is written on the identification
plate. It states the room temperature within which the
appliance can be operated.
Atmosphere grade
SN
N
ST
T
Ventilation
Never cover the ventilation openings in the base panel.
The cooling motor otherwise has has to increase ist
output, and this increases the electricity consumption.
40
Permitted ambient
temperature
+10 °C to 32 °C
+16 °C to 32 °C
+16 °C to 38 °C
+16 °C to 43 °C

Fixing

For secure installation, the appliance screwed to neigh
bouring kitchen furniture and/or units.
It is very important therefore that all bordering furniture
and/or units are fixed securely to the floor and/or walls.
If making structural changes fix the appliance in place
again corresponding to the the installation instructions.

Installation surface

A load bearing base is necessary because of the heavy
weight of the fully laden appliance.
Refer to the following appliance weight table when
loading fully:
-
45.7 cm appliance
-
61.0 cm appliance
-
76.2 cm appliance
In case of doubt, consult an architect or structural
engineer.

Installing and connecting the appliance

!
Caution
The appliance should only be installed and connec
ted by a recognised installation engineer according
to the installation instructions belonging to the
appliance.
After installing the appliance, wait at least ½ hour before
switching on the appliance. During transportation the oil
in the compressor may have flowed into the refrigeration
system.
Before switching on the appliance for the first time,
clean the interior of the appliance (see "Cleaning the
appliance").
250 kg
350 kg
425 kg