Adjustable lat-jet nozzle
-
Cleaning agent container with nozzle
-
Nozzle cleaning pin
The diagram of the most im-
portant functional elements
can be found on the foldout
side.

Overview

1
High-pressure connection on the
A
gun side
2
High-pressure connection on the
washer side
3
High-pressure connection
4
Carrying handle
5
ON / OFF switch
6
Accessories holder
7
Power supply cable
8
Water connection with sieve in-
sert (not visible)
9
Chassis
10
Gun
11
Jet lance
12
Adjustable lat-jet nozzle
13
High-pressure nozzle
14
Cleaning agent container with
nozzle
15
Nozzle cleaning pin

Functional description

The pressure washer is to be used for
washing with a high-pressure water jet. A
detergent can be added if this is required.
For the functions of the operating elements
please refer to the subsequent description.
Ensure that the safety instructions are al-
ways observed!

Technical data

Pressure Washer .........PHD 100 C2
Mains connection .............. 230V~, 50 Hz
Power consumption ....................1450 W
Mains cable .....................................5 m
Weight (incl. all parts) ...................6,1 kg
Safety class ......................................
Degree of protection ......................... IPX5
Inlow temperature t, max. ................40°C
Inlow pressure p, max. .... 0,8 MPa (8 bar)
Operating pressure p ........ 7 MPa (70 bar)
Max. permissible pressure p. ...................
.................................. 10 MPa (100 bar)
Pumping rate, water ................... 5 l/min
Max. pumping rate, water ........ 6,6 l/min
Acoustic pressure level
(L
) ................78 dB(A); K
pA
Sound power level (L
measured ..... 88,8 dB(A); K
guaranteed ........................... 95 dB (A)
Vibration (a
) ....... 0,7 m/s
n
The operating conditions during measuring
and the procedures used for measuring in
accordance with
EN 60335-2-79:2009.
Technical and optical changes can be car-
ried out in the course of further development
without notice. All dimensions, references
and information of this instruction manual are
therefore without guarantee. Legal claims,
which are made on the basis of the instruc-
tion manual, cannot thus be considered as
valid.

Notes on Safety

This Section is concerned with the basic
safety rules when working with the pres-
sure washer.
GB
=3,0 dB(A)
pA
)
WA
=3,0 dB(A)
WA
2
; K=0,15 m/s
II
2
5

Werbung