Updating PCS 7

If you want to update the current PCS 7 version on the "A2 image" (see "PCS 7 software product package (Page 20)"), make
the following settings in the Windows 10 and Server 2012 Control Panel before the installation:
● under "Language"
select the language "English (United States)" for "Display Language" and use the "Move Up" button to place this at the
uppermost position.
● under "Region"
select the language "English (United States)" for "Language for non-Unicode programs" in the Administration tab.
In the PCS 7 Setup, use the update function ("Setup type: Update").

Post-installation of software

Use the "A1 image" for post-installation of software and an associated functional modification of the device (see "PCS 7
software product package (Page 20)"). In this way, you avoid unwanted dependencies, for example, license messages from
software components that are no longer used in the "A2 image".

Image files for data backup

Use the SIMATIC IPC Image & Partition Creator V3.5.1 or higher to create image files for data backup.
Please make sure that your PC has the newest BIOS version before you use the SIMATIC IPC Image & Partition Creator.

ClearType text enhancement for digital display devices

If you use a digital display device on your machine, the "ClearType" feature is preset in your operating system. This
improves the readability of text. This default setting can be reset, depending on the connected monitor type.
You can check whether the "ClearType" function is enabled under Display Properties in the Control Panel.

CD and DVD burners

Note
Risk of system performance limitations
When your device is in online mode, performance limitations or malfunctions may occur during burning of CDs and DVDs.
Always burn CDs and DVDs with your device in offline mode only.

Sound module

Your device is equipped with a Sound Blaster-compatible sound module (onboard).
NOTICE
Adherence to the specified limits for noise immunity and interference emission is not guaranteed
Adherence to the values listed in the technical specifications relating to noise immunity and interference emission is not
guaranteed when using microphone IN.
Always use the LINE OUT port of the sound module for playback.
The sound module is not approved for microphone IN.