● SIMATIC IPC647D (Type 1), redundant BCE communications card:
Additional slot 4
● SIMATIC IPC647D (Type 2), redundant CP1623:
Additional slot 1
● SIMATIC IPC647D (Type 2), redundant BCE communications card:
Additional slot 1
● SIMATIC IPC847D, redundant CP1623:
Additional slot 2
● SIMATIC IPC847D, redundant BCE communications card:
Additional slot 2
Slot for multi-monitor graphics card
You can expand your device with a multi-monitor graphics card. Use the following slots for this.
● SIMATIC IPC647D (Type 1): Slot 2
● SIMATIC IPC647D (Type 2): Slot 1
● SIMATIC IPC847D: Slot 8
Slot for hardware RAID controller
If your device is equipped with a hardware RAID controller, it is installed in one of the following slots:
● SIMATIC IPC647D (Type 1): Slot 1
● SIMATIC IPC647D (Type 2): No configuration with hardware RAID controller
● SIMATIC IPC847D: Slot 6
A slot next to a hardware RAID controller (see the following list) is equipped with a perforated cover for better ventilation.
● SIMATIC IPC647D (Type 1): Slot 4
● SIMATIC IPC847D: Slot 5
For configurations with hardware RAID controllers, these slots must not be used for any other modules.
Slots for CS 275 interface module N-PCI
You can expand your device with a CS 275 interface module N-PCI in engineering and operator systems.
Use the following slots for this.
● SIMATIC IPC647D (Type 2): Slot 3
● SIMATIC IPC847D: Slot 10
You do not have to change the existing BIOS settings (in particular ACPI).
Drivers for components and operating systems
The drivers for components are stored in the "C:\Windows\ConfigSetRoot\Drivers" folder of the restored system.
SIMATIC IPC647D/847D
A5E41792571-AA, 7/2017
27