Enabling/disabling time synchronization

Time synchronization with an Internet server is enabled in the Control Panel.
When time synchronization is enabled, an entry may be generated in the event display. This entry can be cleared by
disabling time synchronization.
1. Select "Control Panel > Date and Time > Internet time" tab
2. Disable the option "Synchronize with an Internet time server".
3. Confirm your entries.
Before entering the device into a domain, you should enable time synchronization once again. You can find information on
this in the section: Entering a SIMATIC Industrial PC in a domain (Page 22).

Interfaces and connections

SIMATIC IPC647D can be ordered in two versions that differ in regard to the available PCI Express slots on the
motherboard. The following therefore distinguishes between the two types based on the number of available PCI Express
slots:
● SIMATIC IPC647D with 4 x PCI Express: Referred to as Type 1 in the following
● SIMATIC IPC647D with 2 x PCI and 2 x PCI Express: Referred to as Type 2 in the following

Ethernet interfaces

The Ethernet interfaces in the device are preset to DHCP. If you are not running a DHCP server, configure the IP addresses
manually.
The Ethernet interfaces are configured and used as follows:
● Onboard Ethernet interface "X1P1": Terminal bus 1
● Onboard Ethernet interface "X2P1": Reserve

Slots for internal expansion cards

Note
Use the module clamp to secure the expansion cards installed at a later time. We recommend securing the cards in direction
of the device front. When installing the clamp, make sure that you do not damage any of the components on the expansion
cards.
The PCI expansion cards should be used as plant bus as follows:
● SIMATIC IPC647D (Type 1), CP1623:
Slot 3 (pre-installed with IE bundle)
● SIMATIC IPC647D (Type 2), CP1623:
Slot 4 (pre-installed with IE bundle)
● SIMATIC IPC847D, CP1623:
Slot 3 (pre-installed with IE bundle)
● SIMATIC IPC647D (Type 1), BCE communication card:
Slot 3 (pre-installed with BCE bundle)
● SIMATIC IPC647D (Type 2), BCE communication card:
Slot 4 (pre-installed with BCE bundle)
● SIMATIC IPC847D, BCE communication card:
Slot 3 (pre-installed with BCE bundle)
● SIMATIC IPC647D, (Type 1) redundant CP1623:
Additional slot 4
26
SIMATIC IPC647D/847D
A5E41792571-AA, 7/2017