36 | GRIP F 20 | Maintenance
6.
Maintenance
6.1

Recommended lubricants

Component
Lubricant
Gear unit
Mineral lubricant
Compressed air
Mineral lubricant
system
Tab. 1:
List of lubricants
!
The manufacturer does not accept any liability for
damage arising from the use of lubricants with
properties differing from those specified (Standard).
6.2

Cleaning and maintenance

DANGER - Risk of electric shock from live
parts
Risk of electric shock from contact with
electrical components.
Always switch off the GRIP F 20 at the
master switch before performing any
cleaning or maintenance work.
Unplug the mains connector.
DANGER - Risk of crushing by parts on
application of pressure
Risk of crushing due to the abrupt movement
of components or parts.
Always disconnect the GRIP F 20 from the
compressed air supply before performing
any cleaning and maintenance work.
Regular cleaning and maintenance of the GRIP F 20 are
essential to ensure maximum performance and proper
operation of the GRIP F 20.
Maintenance work must be performed by the operator
on the basis of the manufacturer's specifications as
follows.
6.2.1

Maintenance intervals

Maintenance
Clean the mechanical moving parts, spray
them with nebulized oil or cherosene and lube
with appropriate grease
Remove the condensate from the filter
assembly.
Check oil level in the oil nebulizer.
Check transmission belt tensioning in order to
avoid its sliding.
|
1 695 108 479
2016-09-26
Maintenance
Check the oil level in the gearbox and keep it
Standard
always between minimum and maximum level.
ISO 460

Change oil in the oil nebulizer.

DIN 51502-CLP
ISO 34-98-CC
ISO VG 32
6.2.2
1. Turn left the red button placed in the lower part of
2. Remove the accumulated condense by pressing the
3. Turn back in previous position the red button placed
6.2.3
4. Disconnect pneumatic connection.
5. Unscrew the tank cap on the oil nebulizer.
6. Top up oil (see lube table).
6.2.4
1. Disconnect pneumatic connection.
2. Unscrew the tank cap on the oil nebulizer.
3. Discharge oil and dispose it (see chap. 7.3).
4. Top up with new oil (see lube table).
x
x
x
x
Condensate removal
the water separator.
same button.
in the lower part of the water separator.
Nebulizer oil refill
Change oil in the oil nebulizer
x
x
OMCN spa