CONVERSION OF GAS SUPPLY
The constructor has tested the appliance with its
own mains gas, identified by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
2 - Change the top burner nozzles (see page 17).
3 - Change the top burner pilot light nozzles
(see page 18).
4 - Adjust the minimum settings of the gas control
valves of the burners (see page 15).
5 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make
sure that there are no gas leaks or mal-
functions.
IT
GB
TESTING OF THE APPLIANCE
DE
Important
Before it is put into service, the system must
FR
be tested to check the operating conditions of
every single component and identify any mal-
functions. In this stage, it is important to
ES
check that all health and safety requirements
have been complied with in full.
To test the system, make the following checks.
1 - Turn on the gas supply tap and check that the
connections are right.
2 - Check that the mains gas is the same as that
used for commissioning of the appliance, and
carry out the conversion procedure if necessary
(see page 14).
English
A
3 - Check that the hob burners are igniting correct-
ly and their combustion.
4 - Check the gas pressure and flow-rate at mini-
mum and maximum settings and adjust if nec-
essary (see pages 9).
5 - Check that the safety thermocouple is working
correctly.
6 - Check that there are no gas leaks.
7 - Check that the nameplates specify the correct
gas for the country of use.
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.
- 14 -
IDM-39603601220.tif
IDM-39602002500.tif