[P3.2] Operation mode (1 - room heating
2 - domestic hot water warming, 3 - room heating and
d. h. w. warming, 4 - changeover to cooling mode,
5 - Party mode
Service group S1
Service group S1 is intended for thermostat's service settings. In
program group S1 are the following parameters; (factory setting):
- [S1.1] Controlled heating system
(1 - heating circuit (ON / OFF control),
2 - heating circuit (ON / OFF control) and dom. hot water,
3 - heating circuit (3 point control),
4 - heating circuit (ON / OFF control) + boiler with built in
domestic hot water storage tank,
5 - floor heating,
6 - domestic hot water,
7 - gas boiler Junkers or Vaillant (flame power modulation),
8 - gas boiler Junkers or Vaillant and d. h. w. circulation),
9 - heating circuit (ON / OFF control) and cooling;
(depends on installed module - see Table 2)
- [S1.2] Auxiliary sensor (- - - no sensor, 1 - room temp. sensor,
2 - outdoor temp. sensor, 3 - d. h. w. temperature sensor,
4 - floor temp. sensor, 5 - boiler temp. sensor,
6 - stand-pipe temperature sensor)
(depends on installed module - see Table 2)
- [S1.3] Room temperature
(1 - built-in sensor, 2 - auxiliary sensor,
3 - min. measured temperature, 4 - max. measured tem-
perature, 5 - average temperature); (1 °C)
- [S1.4] Auxiliary temperature sensor calibration
(-2 °C ÷ 2 °C); (0 °C)
- [S1.5] Measured temp. roundup
(0.1 °C, 0.2 °C, 0.5 °C, 1.0 °C) ; (0,5 °C)
- [S1.6] Heating optimisation
Settings manual
1
); (3)
1
(- - - deactivated, 1 - activated); (2)
28