Index of protection
Storage temperature
Transport temperature
Operating temperature
Altitude
Ambient humidity
Humidity during storage
Vibration
Shocks
Immunity
Radiated and conducted
emissions
UL standards

1.5 - Radio-frequency interference

1.5.1 - General
Variable speed drives use high-speed switches (transistors,
semi-conductors) which switch high voltages (around
550VDC for 3-phase drives) at high frequencies (several
kHz). This provides better efficiency and a low level of motor
noise.
As a result, they generate radio-frequency signals which may
disturb operation of other equipment or distort measurements
taken by sensors:
- due to high-frequency leakage currents which escape to
earth via the stray capacity of the drive/motor cable and that
of the motor via the metal structures which support the motor
INSTALLATION AND MAINTENANCE
VARMECA 30
Variable speed motor or geared motor
GENERAL INFORMATION
IP 65
- 40 °C to + 70 °C Conforming to standard IEC 68-2-1.
- 40 °C to + 70 °C
- 20 °C to + 50 °C (with power derated by 1% per °C, above 40 °C)
< 1000 m without derating.
The maximum authorised altitude is 4000 m, but above 1000 m, the continuous output current
should be derated by 1% per additional 100 m over 1000 m (eg: for an altitude of 3000 m,
derate by 20%).
95% non condensing
93%, 40 °C, 4 days
- Exposed product: 0.01 g
- Sinusoidal vibration:
• VMA 31/32 : 2-9 Hz 3,5 ms
• VMA 33/34 : 2-6 Hz 3,5 ms
in accordance with standard IEC 68-2-6.
Packaged product: 15 g, 6 ms, 500 times/direction in all 6 directions in accordance with
standard
IEC 68-2-29.
Conforming to EN61000-6-2
Conforming to EN50081-2 with internal filter
Conforming to UL 508 C (E211799)
Level
2
/Hz 1 hr in accordance with standard IEC 68-2-34.
-2
- 9-100 Hz 10 ms
-2
-2
- 6-100 Hz 5 ms
-2
- by conduction or feedback of R.F. signals on the power
supply cable: conducted emissions
- by direct radiation near to the mains supply power cable or
the drive/motor cable: radiated emissions
These phenomena are of direct interest to the user.
The frequency range concerned (radio frequency) does not
affect the energy distribution company.
Conformity of the drive is only assured when the
mechanical and electrical installation instructions
described in this manual are adhered to.
3776 en - 07.2007 / h
43

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis