NOTE: For multi-split type air conditioners, one outdoor unit can be matched to different
types of indoor units. All of the pictures in this manual are for demonstration purposes
only. Your air conditioner may be slightly different, if similar in shape. The following pages
introduce several kinds of indoor units that can be matched with the outdoor units.

Operating Conditions

Use the system under the following temperatures for safe and effective operation. If the air
conditioner is used under different conditions, it may malfunction or become less efficient.
Indoor Temperature
Outdoor Temperature
Features
Protection of the air conditioner
Compressor protection
• The compressor cannot restart for 3 minutes
after it stops.
Anti-cold air (Cooling and heating
models only)
• The unit is designed not to blow cold air on
HEAT mode, when the indoor heat exchang-
er is in one of the following three situations
and the set temperature has not been
reached.
A)
When heating has just started.
B)
During defrosting.
C)
Low temperature heating.
• The indoor or outdoor fan stop running
when defrosting (Cooling and heating
models only).
Defrosting (Cooling and heating models
only)
• Frost may be generated on the outdoor
unit during a heat cycle when outdoor
temperature is low and humidity is high re-
sulting in lower heating efficiency in the air
conditioner.
• Under these conditions, the air conditioner
will stop heating operations and start de-
frosting automatically.
• The time to defrost may vary from 4 to 10
minutes, depending the outdoor tempera-
ture and the amount of frost buildup on the
outdoor unit.
◄ Page 8 ►
COOL Mode
17-32°C(62-90°F)
0-50°C (32-122°F)
-15-50°C (5-122°F)
(For models with low-temp
cooling systems)
0-60°C (32-140°F)
(For special tropical models)
Auto-Restart
In case of power failure, the system will im-
mediately stop. When power returns, the
Operation light on the indoor unit will flash. To
restart the unit, press the ON/OFF button on
the remote control. If the system has an auto
restart function, the unit will restart using the
same settings.
White mist emerging from the indoor unit
• A white mist may be generated due to a large
• A white mist may be generated due to mois-
Noise coming from the air conditioner
• You may hear a low hissing sound when the
• You may also hear a low "squeaking" sound
• A noise may be heard due to the louver
HEAT mode
0-30°C (32-86°F)
-15-24°C (5-75°F)
-7-24°C (19-75°F)
temperature difference between air inlet and
air outlet on COOL mode in places with high
relative humidity.
ture created in the defrosting process when
the air conditioner restarts in HEAT mode
operation after defrosting.
compressor is running or has just stopped
running. This sound is the sound of the refrig-
erant flowing or coming to a stop.
when the compressor is running or has just
stopped running. This is caused by tempera
heat expansion and cold contraction of the
plastic parts in the unit when the tempera-
ture is changing.
restoring itself to its original position when
power is first turned on.
DRY mode
17-32°C(62-90°F)
0-50°C (32-122°F)
0-60°C (32-140°F)