130 Nm (96 lbf-ft). Fit the protection device. Connect the free end to the application.
Close the air valve (6) and connect the air hose to the air connection (1).
Connect the hoses to the oil inlet (2) and the oil return (3).
Put the free ends of the oil hoses into the oil container. Make sure that the end of
the oil suction hose is completely immersed in the oil.
Make sure that the release valve (5) is open. Open the air valve (6) to start the
THAP...E Operate the THAP..E until no air bubbles can be seen in the oil return
hose (3).
To start the delivery of oil, close the release valve (5).
Note: Oil can circulate through the return hose, even when the release valve is closed.
If the THAP...E is connected to a high-pressure pipe or flexible pressure hose, the air
must be removed from the pipe or hose. Often this can be done by slightly loosening
the pipe or hose connection on the application, until air free oil emerges.
After de-airing the pipe or hose, retighten the connection.
To stop the THAP...E, open the release valve (5) to release the oil pressure, then close
the air valve (6)

4.1 Protection device

Protection device (THAP E-PC1) must be fitted when connecting a high pressure pipe to a
THAP 300E or THAP 400E.
1
3
10
2
4
130 Nm
96 lbf-ft Max
SKF THAP 030E 150E 300E 400E

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Thap 030eThap 400Thap 300e