• The power supply must be adequate to supply the required power indicated in the radiographic system's nameplate
data.
• In order to safeguard one's warranty rights, please fi ll in the enclosed Warranty Document, immediately after the
installation is completed, with the technician's help.

TRANSPORT CONDITIONS

The X-M
AC radiographic system travels at the receiver's own risk.
®
IND
All claims for damage or loss regarding the shipment must be identifi ed in the presence of the shipping agent.
In the case of loss, or actual or suspected damage, the receiver should indicate the proper reserves on the way-bill or on
the consignment note.

SAFETY WARNINGS

The safety recommendations listed below should be followed when using the X-M
CAUTION
PROTECTION AGAINST RADIATION
"The general principles regarding safety and protection of workers and people" must always be applied when
using the unit:
1- Justifi cation of the examination
2- Protection Optimisation (ALARA)
3- Reduction of the limits of individual dose and risks.
The radiographic system must only be used by authorized and qualifi ed personnel.
All personnel present during the radiographic examination must comply with safety measures foreseen with
regard to protection from radiation.
For the operator's safety, a distance of more than 2 meters from the radiographic unit must always be
respected.
To protect the patient from unnecessary exposure to radiation, additional anti-radiation protections may be
used whenever necessary (aprons, collars, etc.).
CAUTION X-RAYS
CAUTION
MECHANICAL RISK
Before removing the tubehead from the positioning arm, RELEASE THE SPRING because the joint might burst
open and hit the operator.
CAUTION
ELECTRIC SAFETY
The radiographic system contains high voltage.
When inspecting internal parts, always turn off the power before touching any electric part.
The unit must be used only in environments that are in full compliance with all electric safety standards for
medical environments.
The unit is NOT equipped with protections against the penetration of liquids; it will therefore be necessary to
make sure that no water or other liquids penetrate inside so as to avoid short circuits or corrosion.
Always disconnect the radiographic system from the power supply before cleaning and disinfecting operations.
8