Installation

heater is operated via the load shedding relay prior to any
other appliance.
Central thermostatic valve
Use the thermostatic valve for central premixing when
operating an instantaneous water heater with preheated
water, for example. For use in shower operation, the valve
must be set to a maximum of 55 °C.
9. Installation
9.1

Installation location

The appliance is exclusively designed for installation on
a solid wall. Ensure the wall offers adequate load bearing
capacity. Always install the appliance vertically in a room
free from the risk of frost.
9.1.1 Oversink appliance installation
WW
9.1.2 Undersink appliance installation
9.2 Preparing for the appliance installation
9.2.1 Opening the appliance
» Release the snap lock using a screwdriver (1).
» Flip up the appliance cover and remove it (2).
1
32
kW
kW
WW
2
9.2.2 Information regarding the appliance with
changeover connected load
In its delivered condition the appliance is set to 21 kW.
When changing to a different output, carry out the fol-
lowing steps:
» Re-plug the coding card in accordance with the se-
lected output. Observe the corresponding fuse pro-
tection required. For this, see chapter Specification.
» Tick the selected output on the type plate using a
permanent marker.
9.2.3 Removing the lower back panel section
» Press both locking hooks inwards. Pull the lower
back panel section forwards to remove.
1
9.2.4 Securing the mounting bracket
38°
» Mark out the mounting bracket fixing holes using the
OFF
3s
installation template. You can also use any suitable
55°
mounting bracket that is already installed.
» Secure the mounting bracket with two suitable
screws and rawl plugs. The screws and rawl plugs
are not part of the standard delivery.
» Insert the threaded stud supplied into the mounting
bracket.
You can secure the appliance at the bottom with two addi-
tional screws. This is required if the appliance is installed
with water connections on finished walls (installation on
finished walls).
9.2.5 Preparing the power cable
≥ 30
1 Securing the twin nipples
1