* You can set the values of these consumption displays
to zero.
** The clock has to be reset after a power interruption.
Anti-scalding protection
Your qualified contractor can set a permanent tempera-
ture limit (see chapter "Customer service mode") to pre-
vent any water being drawn from the appliance at tem-
peratures that could lead to a risk of injury.
Air detection
The appliance is equipped with an air detector that largely
prevents damage to the heating system. If, during opera-
tion, air is drawn into the instantaneous water heater, the
appliance shuts down for one minute, thereby protecting
the heating system.

4. Operation

4.1
Operation and displays on the appliance
Temperature display
Bar graph showing output
Second display
for example time
Memory buttons 1 and 2
Info and ECO button
ECO display
Rotary selector for temperature
selection
Display range for:
"Wellness"
"ECO" mode
"Second line"
Display area for additional information; notify your contractor if these symbols are shown.
"Error"; see chapter "Customer service mode"
"Service"; see chapter "Customer service mode"

4.1.1 Setting the temperature

Operation
4.1.2 Allocating memory buttons
"Automatic water volume control"
"Childproofing"
"Clock"
»
Temperature selection 30 ... 60 °C, infinitely adjust-
able.
»
Required temperature 30... 60 °C to be saved
should be selected.
»
Hold down button 1 or 2 for three seconds.
Display field for additional information:
Service, error
Backlighting
Display range for:
Wellness, automatic water volume con-
trol, ECO,
childproofing, second display, clock
"Orientation light"
Display indication
For example 43 °C.
OFF = heating is switched off.
For example 38 °C.
For example 38 °C and 43 °C.
Display flashes briefly once; temperature is saved.