1.5
DHW output
Subject to season, the following maximum mixed water or draw-off capacities result for different cold water
temperatures (see Table 1):
=
Cold water inlet temperature
1
=
Mixed water temperature
2
=
Outlet temperature.
3
2
kW
18
l/min *
1
6 °C
8.0
10 °C
9.2
14 °C
10.7
Table 1
* Table values relative to a rated voltage of 400 V. The outlet volume is subject to the available supply pressure
and the available mains voltage.
1.6
Recommended settings when using a thermostatic valve
To safeguard the function of the thermostatic valves, set the instantaneous water heater to its maximum
temperature (temperature selector to the right end stop).
1.7
First aid in case of faults
Check all fuses.
Check taps/valves and shower heads for scaling or contamination (see also "6. Troubleshooting").
some of the details from the type plate (
DDLE Basis . . No.: . . . . . . - . . . .
1.8
Maintenance and care
!
1.9
Operating and installation instructions
!
= 38 °C
21
24
27
9.4
10.7
12.1
10.7
12.3
13.8
12.5
14.5
16.1
A
- . . . . .
= 60 °C
3
kW
18
l/min *
1
6 °C
4.8
10 °C
5.2
14 °C
5.6
18):
For users and contractors
21
24
27
5.6
6.4
7.2
6.0
6.9
7.7
6.5
7.5
8.4
25