Service.

The stove should be inspected by a gas engineer once a year� As a minimum, this in-
spection should ensure that the stove is working correctly and is safe to use�
Service.
Turn off the stove and shut off the gas supply� Ensure the stove is com-
pletely cold before starting� Rais cannot be held responsible for injuries
arising from touching a hot stove�
Proposed service procedure�
1� Protect the floor by laying down a mat or other covering�
2� Open the door and carefully remove the ceramic logs including em-
bers�
3� Use a vacuum cleaner to clean the burner and perforated sheet�
4� Lift and remove the secondary burners� Lift out the perforated sheet�
5� Vacuum the entire burner�
6� Clean the pilot burner joint with a soft brush and a vacuum cleaner�
The thermosensors must not be bent or adjusted�
7� Put on the gas supply and check for leaks� Check that the burners
and pilot unit are in good condition and work�
8� Replace the perforated plate
9� Replace embers and ceramic logs�
10� Check the flue gas system and chimney terminal and ensure it is not
blocked�
11� Turn on the stove and check the set pressure�
12� Ensure the stove is safe to use�