English
User instructions
USER INSTRUCTIONS
GENERAL NOTES
NB!
The wiring for valves and receiver must be closed off before
the ignition is put on� Failing to do so could damage the
electronic system�
Batteries – Handset
•
Low battery indicator on the handset�
Batteries – Receiver
•
Low battery indicator: frequent beeping for 3 min-
utes when the motor is running.
•
An AC adapter connected to a socket can be used
instead of batteries.
•
The module for controlling the ventilator speed and
light/damper include a power point and batteries in
the receiver for an automatic reserve power supply
in the event of power failure.
•
If the mains adapter and battery are not used,
it is recommended that they are replaced at the
start of each heating season�
•
Old or dead batteries must be quickly removed�
If the batteries are left in the unit, they may
overheat, leak and/or explode�
•
Do NOT expose the batteries (even during
storage) to direct sunlight, strong heat, fire,
moisture or strong impacts� All these factors
could contribute to the battery overheating,
leaking and/or exploding�
•
The batteries must be stored within the rec-
ommended temperature range� (Range of the
battery's ambient temperature: 32-131 °F (0-55
°C])�
•
New and old batteries should not be used at
the same time� The same applies to batteries of
different makes� If different batteries are used
at the same time, this could contribute to the
battery overheating, leaking and/or exploding�
Software version
Press on the
and
Now the software version is displayed�
Model number of the handset
Press on the
and
time� Now the model number of the handset is dis-
played�
Deactivation of functions
1�
Install batteries All icons are displayed and flash�
2�
While the icons are flashing, press on the
relevant function button and hold down for 10
seconds�
3.
The function icon remains flashing until deactiva-
tion is completed. Deactivation has been completed
when the function icon and two horizontal lines are
displayed.
buttons at the same time�
buttons at the same
attika
RAIS/
- User manual for VIVA L Gas
NOTE:
When you press on a deactivated button,
nothing happens and two horizontal lines are dis-
played�
NOTE:
Deactivation remains in effect after replace-
ment of batteries�
Activation of functions
1�
Install batteries All icons are displayed and flash�
2�
A function is activated by pressing the relevant
button and holding it down for 10 seconds�
3�
The function icon continues to flash until activa-
tion is completed� Activation is completed when
the function icon is displayed�
The following functions can
be deactivated/activated
•
CHILD PROOFING
•
PROGRAM MODE
•
THERMOSTATIC MODE (also deactivates PRO-
GRAM MODE)
•
ECO MODE
•
LIGHT/DAMPER (OPERATION)
•
ROOM VENTILATOR (OPERATION)
•
HELP FUNCTION
•
COUNTDOWN TIMER