60 | VLS 5140 | Foundation Plans
7.2.2
Continuous footing
min. 1000
max. 2250
400
A–A
Ø120
Fig. 29:
Foundation plan 3 (all dimensions in mm. Arrow = direction in which vehicle approaches)
(1) Before starting construction work, it must be
ensured that the most up-to-date version of the
foundation plan is available.
(2) It is not possible to use an axle lift in conjunction
with continuous footing.
(3) The four base plates must be perfectly level and
even. The maximum height deviation is 5 mm. Levelling
is required!
(4) Front drive-on flaps are optional. The standard
version is equipped with a rigid roll-off guard.
(5) Adequate drainage must be ensured.
(6) Connections in the operating unit
Mains connection
3/NPE; 400 V; 50 Hz
Compressed air
8 – 10 bar (provide service unit)
(7) Use a conduit with Ø 120 mm for the connecting
cables.
|
1 689 978 572
2014-06-06
2320
765
790
Ž

1610
65
580
1030
Ž
765
790
1610

765
580
Ž
580
Ž
765
min.
210
(8) Concrete quality
Min. thickness
210 mm
of concrete
Quality of concrete
C 20/25
B 4710-1
Surface
Horizontal and even
(gradients max. 0.5 %)
Reinforcement
BSt 500 M, Q131
top: asx,y = 3.77 cm
bottom: asx = 2.57 cm
(9) Lifting platform
Recess depth
VLS 5140
170 mm
VLS 5140 A
220 mm
VLS 5140 L
170 mm
Secondary lift
220 mm (compensating elements
at floor level:
are required in front of and behind
the secondary lift)
VLS 5140 LA
220 mm
2100
450
170/220
Œ