Compensate difference in runway height
1. Set the program selector switch to "2".
2. Press the confirmation button.
 Both LEDs light up green.
 Program 2 is selected.
3. Move the runways to a height of approx. 1,500 mm.
4. Compensate the height of both runways using the
emergency buttons S9 and S10.
5. Press the confirmation button.
 Both LEDs flash green.
"
The identical height setting is now saved.
Set upper cut-out point
1. Set the program selector switch to "3".
2. Press the confirmation button.
 Both LEDs light up green.
 Program 3 is selected.
3. Move the runways to their maximum height
(1,830 mm) using the emergency button S1.
4. Press the confirmation button.
 Both LEDs flash green.
"
The upper cut-out point is now saved.
Set "Foot protection" safety level
1. Set the program selector switch to "6".
2. Press the confirmation button.
 Both LEDs light up green.
 Program 6 is selected.
3. Lower the runways to a height of 200 – 250 mm.
4. Press the confirmation button.
 Both LEDs flash green.
"
The "Foot protection" safety level is now saved.
Restore normal operation
1. Set the program selector switch to "0".
2. Press the confirmation button.
 Both LEDs light up red.
"
The lifting platform is now ready for normal operation.
Robert Bosch GmbH
Installation | VLS 5140 | 51
3.10.4
Displacement sensor basic setting
The displacement sensors have an electronic limit stop.
As a result, it is possible that the lower or upper end
position is not reached with motor drive.
Solution:
1. Move the runways to their maximum height
(1,830 mm) using the emergency button S1.
2. Lift the pinion from the toothing.
3. Turn the pinion counter-clockwise until the
mechanical stop, then turn it back for approx. half
a rotation.
4. Lower the pinion into the toothing again.
Fig. 21:
Displacement sensor under the runway
1 Toothed rack
2 Potentiometer
3 Pinion
3.10.5
Test programs
If a fault occurs during a test (programs 7 and 8), the
corresponding error code is stored in the EEPROM.
The control system can then no longer be set to normal
operation.
Solution:
1. Rectify the fault.
2. Restart the test program.
If the test program is completed with no faults, normal
operation can be selected again.
3.11
Performing a test run with the lifting
platform
1. Perform a test run of the lifting platform at nominal