2 2 / / INSTALLING YOUR APPLIANCE
EN

•Gas settings

Appliance intended to be installed in:
FR ...............................cat : II2E+3+
CH - ES - IT - PT .......cat : II2H3+
CY - EE - PL ..............cat : II2H3B/P
LT ...............................cat : I2H
Hourly rate below:
25 mbar at 15°C under 1013 mbar
H
IGH SPEED BURNER
Marking on injector
Nominal heat release rate
Reduced heat release rate
Hourly rate
Hourly rate
S
EMI-FAST BURNER
Marking on injector
Nominal heat release rate
Reduced heat release rate
Hourly rate
Hourly rate
60
H
CM
OB WITH
Total heat release rate
Maximum rate
• Identifying the injectors
The table below shows where the injectors
can be found on your appliance, according to
the type of gas used.
The number is marked on each injector.
Operating voltage :
Total absorbed electric power:
- 2 induction zone model
Hob dimensions:
- Width
- Depth
Weight:
- Dimensions of unit:
- Width
- Height
- Depth
2
GAS BURNERS
60 cm hob with 2 gas burners and 2 induction zones
SR
94
137
220-240 V ~ - 50 Hz
FR-CH
ES-IT
PT
Butane
G30
28-30 mbar
88A
(kW)
3.15
(kW)
0.830
(g/h)
229
(l/h)
62
(kW)
1.50
(kW)
0.620
(g/h)
109
(l/h)
(kW)
4.60
(g/h)
334
(l/h)
GR
SR
62
88A
3100 W (1)
600 mm
518 mm
11.4 kg
549 mm
59 mm
470 mm
44
FR-CH
FR-CH
ES-IT
ES-IT
PT
PT-CY
EE - PL
LT
Propane
Natural
Natural
Gas
G31
G20
37mbar
20 mbar
25 mbar
88A
137
3.15
3.10
0.870
225
295
62
94
1.50
1.50
0.615
107
143
4.60
4.60
328
438
Example:
injector marking 94
94
GR
(1) The heating powers are only given by
way of indication. It will depend on the type
and shape of the cookware.
Subject to modification.
FR
Gas
G25
137
3.10
0.870
343
94
1.50
0.615
166
4.60
509