Herunterladen Inhalt Inhalt Diese Seite drucken

Pneumatic Connections; Electrical Connections - Gemü cPos 1436 eco Original Kurzanleitung

Intelligenter stellungsregler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3

Pneumatic connections

Attention:Observe maximum
actuator control pressure!
Pneumatic connections
DIN ISO
Connection
1219-1
P
1
R
3
V1
V1
V2
V2
V5
V5
A1
2
1436 cPos eco
Designation
Size
Air supply connection
G 1/8
Venting connection
G 1/8
with silencer
Additional air throttle
-
for A1 (connector 2)
Exhaust air throttle for
-
A1 (connector 2)
Check valve
-
Working connection
for process valve
G 1/8
(control function 1
and 2)
4

Electrical connections

Danger of cable break!
Turn electrical
connections max.
360°.
To ensure safe restarting of the
positioner following interruption
of the power supply, the power
interruption must be longer than
3 seconds.
X1
Electrical connections
Connection Pin Signal name
1
2
X1
3
M12 plug
A coding
4
5
14 / 20
4 5
1
max. 360°
3
Uv, 24 V DC supply voltage
I+, 4...20 mA (set value input)
Uv, I-, GND
I+, 4...20 mA (feedback signal)
Uv, Initialization 24 V DC starting
the initialization via digital input
3
2
2
5
1
4
X1

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis