Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SITRANS F-Serie Bedienungsanleitung Seite 37

Ultrasonic flowmeters
Vorschau ausblenden Andere Handbücher für SITRANS F-Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

12.Tighten the sensor Clamping Screw to hold the sensor in place.
13.Observing the UP (upstream) and DN (downstream) orientation, attach the UP and DN
FUH1010 IP65 NEMA 7 Interface Detector Quick Start
Operating Instructions, 06/2014, A5E02428148-AA
procedure for the other sensor
Front View
Spring Clip (Not present on some models)
Sensor Clamping Screw
Spacer Bar
1012 Series Mounting Frame
Figure 3-9
Sensor Installation
cables to the sensors and make snug. Attach the other ends to the UP and DN terminals
of the flow meter (see figure below).
.
Commissioning
3.5 Sensor Installation
Repeat installation
Mounting Strap
Note: Optional 2nd Mounting Strap
shown. . Larger pipes over 76cm (30
inches) may need an additional
support.
Spacer Bar Platform and Clamping
Screw
Spacer Bar Reference Hole
Orientation for Single Beam Sensor at
9 o'clock position
Orientation for Dual Beam Sensor at
10 & 2 o'clock positions
35

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

7me3601-1

Inhaltsverzeichnis