Herunterladen Inhalt Inhalt Diese Seite drucken

Dmx Wiring; Install A Plug On The Power Cord - JB-Lighting VaryLED 3*84 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für VaryLED 3*84:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2.3 DMX wiring

Use a shielded twisted-pair cable with two pairs to connect the serial link. Connect
all pins if you want to upgrade the software in crossload.
If a microphone cable (or any other cable with only one pair) is used the software
can not be updated via DMX line for pin 4 and 5 are not connected.
Pin assignment
Pin 1 = shield
Pin 2 = data -
Pin 3 = data +
Pin 4 = data out -
Pin 5 = data out +
The pin assignment is the same for all VaryLED`s in line.
Connect the DMX-out of the control desk to the first VaryLED in line.
(lighting control desk DMX-Out / VaryLED DMX-In). Connect the second VaryLED
to the first in line, and so on (VaryLED 2 DMX-In / VaryLED 1 DMX-Out).
The DMX-Out of the last unit in line is not occupied unless problems occure. Then
use a termition plug with the last VaryLED in line.(XLR-connector with a 120 Ohm
resistor soldered between pin 2 and pin 3). Problems might occure when the line is
overloaded, e.g.
2.4 Installing a plug on the power cord
Install a plug like described in chapter 2.1.
Connected load: Voltage 230 Volts, frequence 50 Hz, power 240 VA (1,1 Amps)
Connect the fixture to a proper installed grounded system only. If any doubts
on the electrical installations occur, consult a qualified electrician.
In case of damages occuring due to a not propper installed electrical system,
warranty claims will be invalidated.
Don´t use fixtures when top cover is not fixed properly. Contact with electronical
parts can result in risk for life.
Connect fixture only after assuring that the electrical installation fits your demands.
If any doubts occur consult a qualified technican!
WARNING:
!
VaryLED can beam up immediately if Standalone mode active or
DMX-Signal is connected !
JB-lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D-89134 Blaustein Telefon +49 (0)7304-9617-0
20
1
shielded signal cable
2
3
4
5
(Electrical shock 230 V)
1
2
3
4
5

Werbung