2.3 Rigging the fixture

WARNING: Keep fixtures at least 2m away from inflamable articles!
!
The Varyscan P6 can either be placed on the floor or hung on a trussing system in a
vertical or horizontal way. If mounting the unit to walls in a vertical way, the lamplife
might be reduced. To mount the unit on a trussing system use the original JB-lighting
omega brackets with Camloc-connectors. The Camlocs must snap in to be locked
propperly. Alway attach a safety cable to secure the unit.

2.4 DMX wiring

Use a shielded twisted-pair cable with two pairs to connect the serial link. Connect all
pins if you want to upgrade the software in crossload.
If a microphone cable (or any other cable with only one pair) is used the software can
not be updated via DMX line for pin 4 and 5 are not connected.
Pin assignment
Pin 1 = shield
Pin 2 = data -
Pin 3 = data +
Pin 4 = data out -
Pin 5 = data out +
The pin assignment is the same for all Varyscans in line.
Connect the DMX-out of the control desk to the first Varyscan in line (lighting control
desk DMX-Out / Varyscan DMX-In). Connect the second Varyscan to the first in line,
and so on (Varyscan 2 DMX-In / Varyscan 1 DMX-Out). The DMX-Out of the last unit
in line is not occupied unless problems occure. Then use a termition plug with the last
Varyscan in line (XLR-connector with a 120 Ohm resistor soldered between pin 2 and
pin 3). Problems might occure when the line is overloaded, e.g.
22
Always use a safety cable attached to the base!
2
3
4
1
shielded signal cable
5
omega bracket
camloc connector
ring eye for safety
chain
1
2
3
4
5