  • DEUTSCH, seite 38
10 Attachment
Model
Terminal
L/L1, N/L2
U/T1, V/T2, W/T3
B018
-, +1
B1, B2
*1
Remove insulation from the ends of wires to expose the length of wire shown.
*2
If you turn on the internal EMC filter, the leakage current of the drive will be more than 3.5 mA. Use these closed-
loop crimp terminals or equivalent to connect a protective ground wire that has a minimum cross-sectional area of
10 mm
2
(copper wire).
• 8-4NS from JST Mfg. Co., Ltd.
• R8-4S from NICHIFU Co., Ltd.
302
Recommen
Applicable
ded Gauge
Gauge
AWG, kcmil
AWG, kcmil
8
12 - 6
10
14 - 8
8
12 - 6
14
14 - 12
*2
8
12 - 8
YASKAWA TOMPC71061753A YASKAWA AC Drive GA500 Installation and Operation Instruction
Wire
Terminal Screw
Stripping
Length
*1
Size
mm
10
M4
10
M4
10
M4
10
M4
*2
-
M5
Tightening
Torque
Shape
N∙m (in∙lb)
1.5 - 1.7
(13.5 - 15)
1.5 - 1.7
(13.5 - 15)
1.5 - 1.7
(13.5 - 15)
1.5 - 1.7
(13.5 - 15)
2.0 - 2.5
(17.7 - 22.1)