DIP4 - ON
The RADIO COMMAND perform the step by step cyclic command open-
stop-close-open-stop-etc.
DIP4 - OFF
The RADIO COMMAND perform the automatic command:
- the open command, if pressed with the gate completely closed
- the close command, if pressed with the gate completely opened
- no effect, if pressed during the gate opening
- the gate re-open, if pressed while the gate is closing
OPEN BUTTON (COM-OPEN)
The button controls the opening movement when the gate is stationary. If activated while
closing, it reopens the gate.
CLOCK FUNCTION
If you want the Clock Function must request S1 with firmware 05 NOUP for the
CLOCK USE.
ATTENTION: A CLOCK CONNECTED TO S1 with fw 04 or more ACTIVATES THE
OPENING MOVEMENT OF THE GATE WITHOUT HAVING THE PROTECTION OF THE
SAFETY DEVICES!
The Clock Function permits to keep the gate opened even if, for example, the Automatic
Closing is enabled (DIP3 ON) or somebody commands the gate closing.
It is useful during rush hours, when traffic is heavy and the flow is slow (e.g. entrance/exit
of employees, emergencies in residential areas or car parks and, temporarily, for removal
vans) and it's necessary to keep the gate opened.
CLOCK FUNCTION APPLICATION
It is necessary to request a S1 control panel with firmware 05 NOUP specific for
the CLOCK USE.
It can be done by connecting a switch and/or a daily/weekly clock either in parallel to
the OPEN button or instead of the OPEN button. When the control board receives this
command, the gate will open and by keeping this contact closed for all the time of the
gate opening, the Clock Function is automatically activated. In fact, once reached the
open position, the gate will remain opened and all of the control board functions are
blocked. Only when OPEN contact is released, the control board functions are re-activated
and the gate will close immediately.
PEDESTRIAN command (PED.Button - COM)
This command is useful to open the gate partially, just enough, for example, to permit a
pedestrian crossing, see Point E procedure.
From the Pedestrian opening position the Automatic Closing can be enabled or disabled
with DIP3. From the Pedestrian opening position, the gate can be completely opened by
the OPEN or by the K BUTT button or by the RADIO button.
AUTOMATIC CLOSING (from the COMPLETE open position)
The Automatic Closing from the complete open position can be enabled turning ON the
DIP3.
The maximum gap of time that can be programmed is 5 minutes (see Point D).
AUTOMATIC CLOSING (from the PEDESTRIAN open position)
The Automatic Closing from the pedestrian open position can be enabled turning ON the
DIP3. The maximum gap of time that can be programmed is 5 minutes (see Point E).
F
UNCTIONING OF SAFETY ACCESSORIES
PHOTOCELL (PHOT - COM)
In case the switch DIP6 is in the OFF position, the photocells are active both in gate
opening and in gate closing. In this configuration, if an obstacle cuts the photocell beam:
- while the gate is closing, the gate will open
- while the gate is opening, the gate will stop and will restart opening when the
obstacle is removed
- while the gate is still, it will not move neither in opening nor in closing
In case of the switch DIP6 is in the ON position, the photocells are active only in gate
closing.
In this configuration, if an obstacle cuts the photocell beam:
- while the gate is closing, the gate will open
- while the gate is opening, the gate will continue open
- while the gate is still, it will open if a open command is request, it will remain still if
a close command is request.
The photocell input (PHOT - COM) is a NORMALLY CLOSED contact.
In case there are more couple of photocells, the contacts from all the photocell receivers
could be connected in series.
In case the photocells are not installed, this contact must be short circuited with a wire
jump (from PHOT to COM) to permit the gate to operate.
AUTOMATIC CLOSING after the transit through the photocell (DIP17 ON)
This option could be useful to close automatically the gate when the vehicle left and
disengaged the photocell beam. If the DIP17 is turned ON, this function is activated and
the PHOTO input will have two purposes:
- detect the obstacle and prevent the gate movement in according with the DIP6 position
- close the gate as soon as the vehicle leaves the photocell beam
If DIP17 ON and DIP6 OFF
If the gate is opening and a vehicle crosses the photo beam, the gate will stop.
When the vehicle leaves, the gate will close automatically after 1second pause.
If DIP17 ON and DIP6 ON
If the gate is opening and a vehicle crosses the photo beam, the gate will continue
to open. When the vehicle leaves, the gate will stop and then closes automatically
after 1second pause.
If the complete gate open position is reached before the vehicle leaving, the DIP17 will
be ignored and the automatic closing will be managed in according to the DIP3 position.
PAY ATTENTION: it is highly recommended to check photocells operation at least
every 6 months.
SAFETY STRIP (EDGE - COM)
If it intervenes during opening, it inverts the movement and closes for 2 seconds and
then stops.
If it intervenes during closing, it inverts the movement and opens for 2 seconds and
then stops.
If the safety strip remains engaged (NO contact), no automatic movement is allowed.
In case the safety strip is not installed, this contact must be short circuited with a wire
jump (from EDGE to COM) to permit the gate to operate.
PAY ATTENTION: it is highly recommended to check safety-strips operation at least
every 6 months.
SAFETY STRIP ALARM
After the inversion given by the intervention of the safety edge, the gate stops in alarm
mode and this is signaled by the blinker on for 1 minute.
During or after the minute of alarm, the normal gate operations can be restored by
pressing any push button.
TESTING THE SAFETY STRIP equipment (DIP12 ON)
The DIP12 ON enables the Test of safety strip equipment. The Test is performed every
time the gate completes a full opening. It is suitable only if the safety strip device is
equipped with a dedicated power supply input.
In fact, the safety strip equipment power supply input has to be connected to the A+TEST
and A- outputs (DIP12 ON). Automatically, every time the gate completes a full opening,
just before closing, the control board switches OFF the A+TEST and A- power supply
output for a very short time. While the safety strip power supply is switched OFF, if
everything is working fine the safety strip contact (EDGE - COM) must open. In case the
test fails, no other gate manoeuvre will be allowed and the alarm state will be signalled
by the Blinker that will remain on.
NOT ALL THE SAFETY STRIPS CAN BE TESTED, THUS THE SWITCH DIP12 MUST BE
LEFT OFF.
STOP BUTTON (COM-STOP)
During all the gate movement, the STOP button will stop the motor.
If it is pressed when the gate is still and completely open (or partially open in the
pedestrian position), automatic closing will be temporarily disabled even if DIP3 is turned
ON. Therefore, a new command will be needed to close the gate.
FUNCTIONING IN DEAD MAN MODE WHEN THE SAFETY DEVICES ARE FAILING
If the safety edge fails or remains engaged for more than 5 seconds, or if photocell
fails or remain engaded for more than 60 seconds, the OPEN, CLOSE, K BUTTON and
PEDESTRIAN commands will work only in dead man mode.
The signal that this mode has been activated is given by the blinking of the programming
led.
With the blinking of the programming led, the opening and closing operation are allowed
only with the command button pressed and held. The radio commands and that of
automatic closing, will be excluded, since their use in this mode, is not allowed by the
norms.