Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Cleaning And Care; Troubleshooting - Parkside PDSS 400 A1 Bedienungs- Und Sicherheitshinweise

Druckluft-drehschlagschrauber mit doppelschlagwerk
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
After initial use / Maintenance / Cleaning and Care / Troubleshooting
must be disconnect from the compressed air
supply
.
2
Switch off the compressor.
Briefly activate the trigger
equipment to release any residual com-
pressed air.
Now pull back the safety on the connec-
tion coupling of your compressed air
hose.
Now remove the hose from the plug nip-
ple
6
.
Careful when putting the device
down. Always put down the device so it
does not rest on the trigger. This could po-
tentially result in inadvertent activation of the
tool, which in turn could result in hazards.
z Maintenance
ATTENTION! All maintenance must be
performed by trained individuals. Follow the
specified maintenance instructions to ensure
a long life and proper operation of this
quality product.
Disconnect equipment from the com-
pressed air source when performing
maintenance and care.
Check the condition of wear and tear
items and accessories with each mainte-
nance.
Note: Daily cleaning and regular lu-
brication are an absolute necessity for
smooth operation.
Only use special tool oil with a high vis-
cosity (thin fluid). Oil for compressed air
tools or SAE10-20 motor oil are suitable.
ATTENTION! Do not use other (espe-
cially high viscosity) lubricants. Malfunctions
or permanent damage may otherwise occur.
40
GB/IE
The following lubricating options are
available:
of the
a) via the lubricator
3
b) via oil-mist generator
Note: Regular lubrication is imperative
to ensure the longest possible life for your
compressed air de- vice. We recommend
continuous lubrication via the included
lubricator
z Cleaning and Care
z Troubleshooting
After every maintenance verify the equip-
ment is still operating as originally.
Fill the lubricator
10
of oil by first unscrewing the inlet screw
from the lubricator
10
Now install the lubricator in the com-
pressed air supply as described in chap-
ter „Establishing connections".
If a complete maintenance unit with oil-
mist generator is installed on your com-
pressor the lubricator
sarily need to be mounted.
To use the oil-mist generator plug the
plug nipple
6
directly into the equip-
ment and connect with your air hose.
10
.
Always store your air tools / equipment
in dry locations.
No maintenance is required beyond the
above lubrication and cleaning.
Only clean the tool with a dry cloth.
Never clean with fluids such as petrol,
solvents or water.
Do not allow liquids to enter the equipment.
10
included with a bit
.
10
does not neces-

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis