Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; 19 6.1 Measuring Range, Accuracy And Resolution; 19 6.2 Nose Level; Dimensions And Weights - Bosch BEA 050 Produktbeschreibung

Bosch-emissions-analyse
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
6.

Technical Data

i
The device is set ex-factory to 230 V ±10 %, 50/60 Hz.
6.1
Measuring Range, Accuracy and Re-
solution
Exhaust-gas analyzer module (AMM)
Components
Measuring Range
CO
0,000 ... 10,00 %vol
CO
0,00 ... 18,00 %vol
2
HC
0 ... 9999 ppm vol
O
0,00 ... 22,00 %vol
2
Lambda
0,500 ... 9,999
CO
0,00 ... 10,00 %vol
vrai
(not in Germany)
NO
0 ... 5000 ppm vol
Accuracy Class 1 and Class 0 as under OIML R99 Ed.
1998.
6.
Nose Level
Emission sound-pressure levels in the diagnosis mode
in accordance with EN ISO 11200: L
6.

Dimensions and Weights

Function
Dimension H x B x T:
Weight
Bosch Diagnostics
Resolution
0,001 %vol
0,01 %vol
1 ppm vol
0,01 %vol
0,001
0,01 %vol
1 ppm vol
= 46 dB(A).
pA
Specification
approx. 210 x 390 x 390 mm
approx. 13 kg
Technical Data | BEA 050 | 
6.
Temperature, Air pressure limits
Function
Operating temperature
Storage temperature
Ambient air pressure
6.5

Exhaust sample

6.5.1
Exhaust sample probe 1 60 90 09:
Constant load for viton hose 200 °C max.
Peak load 250 °C max. for < 3 min.
6.5.
Partial load probe (optional extra)
1 60 90 06:
Constant load for viton hose 200 °C max.
Peak load 500 °C max. for ≤ 6 min.
en
Specification
5 °C − 40 °C
-20 °C − 65 °C
700 hPa − 1100 hPa
|
1 689 979 832
2007-05-09

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis