- Select the desired amperage on the welding current dial
- Place the gas nozzle on the ignition location so that there is a gap of 2 -
3 mm between the tungsten tip and the workpiece (see Fig. 7a)
- Gradually tilt up the welding torch until the tungsten tip touches the
workpiece (see Fig. 7b)
- Raise the torch and pivot it into the normal position - the arc ignites (see
Fig. 7c)
- Start welding
N.B.! To interrupt the welding operation, simply lift the torch away from the
workpiece until the arc goes out. In this case, there will be no filling of the end-
crater at reduced current, and no gas-shielding of the end-crater.
a) Fit gas nozzle
b) Touch workpiece to
ignite arc
Fig.7
Torch tilt angle

CARE AND MAINTENANCE

Warning! Before opening up the welding machine, switch it off, unplug
it from the mains and put up a warning sign to stop anybody
inadvertently switching it back on again. If necessary, discharge the
electrolytic capacitors.
In order to keep your welding machine operational for years to come, you
should observe the following points:
- Carry out safety inspections at the stipulated intervals (see the section
headed "Safety rules")
- Depending on the machine location, but no less often than twice a year,
remove the side panels from the machine and blow the inside of the
machine clean with dry, reduced-blow compressed air. Do not aim air-
jets at electronic components from too close a range.
- If a lot of dust has accumulated, clean the cooling-air ducts.

TECHNICAL DATA

Mains voltage
Mains fuse
Cos phi
Efficiency
Welding current range El - DC
Welding current at
c) Arc is ignited
Apparent power at
Open-circuit voltage
Operating voltage
Protection class
Type of cooling
Insulation category
Value valid for mains voltage 115 V~
1)
8
Warning! If the machine is designed to run on a special voltage, the
Technical Data shown on the rating plate apply. The mains plug and
mains supply lead, and their fuse protection, must be dimensioned
accordingly.
10min / 40°C 35 % d.c.
10min / 40°C 100% d.c.
35 % d.c.
100% d.c.
Electrode
TIG
115 / 230 V~, 50 - 60 Hz
25 A
/ 16 A slow
1)
0.99
89 %
5 - 110
/ 5 - 140 A
1)
110 A
/ 140 A
1)
80 A
/ 100 A
1)
4.5 kVA
/ 6.1 kVA
1)
3.3 kVA
/ 4.4 kVA
1)
93 V
20.2 - 25.6 V
10.2 - 15.6 V
IP 23
AF
B
S, CE