Herunterladen Inhalt Inhalt Diese Seite drucken

Becker BOM 850C-II Handbuch Seite 45

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Menu 9:
Adjustment other operating modes
1. Select menu item "9".
After approximately 2 seconds, the display fl ashes and shows the set value of the operating mode.
The factory setting is "0".
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) buttons.
Menu value Description
0
Normal operation
1
Normal operation
with ventilation
settings
2
Partial opening of
side sectional door
5
OPEN-CLOSE
operation
6
Automatic closing
('AR')*
7
Automatic closing
('AR')*
8
Automatic closing
('AR')*
9
Automatic closing
('AR')*
Remarks:
- *: A photoelectric sensor must be installed.
3. Press the programming button (PROG button) (D).
In setting 0, 1, 2 and 5 value "0" is displayed. End of menu (if necessary, continue with power learning cycle).
In setting 6, 7, 8 and 9 value "A" is displayed. Continue with menu "A".
Warning:
Automatic door - Do not stand in the movement area of the door, because it may start
unexpectedly!
Remarks
Factory settings
NO FUNCTION
NO FUNCTION
After pulsing in CLOSE position, the drive starts and the door moves
into end position OPEN. Another pulse during upward motion has no
effect and the door continues to open. After generating a pulse in OPEN
position, the door closes. When generating a pulse during closing, the
door stops and opens again.
A pulse always causes an opening of the door. After the open time and
warning time (setup menu A) the door closes automatically.
An interruption of the photoelectric sensor during closing causes stop
and reverse direction. Interruption during opening has no effect.
Function as in point 6, however, an interruption of the photoelectric
sensor during open time causes early termination of open time and the
warning time starts.
Function as in point 7, however, a pulse during open time causes early
termination of open time and the warning time starts.
Function as in point 8, but without early warning phase.
Installation
45

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis