Herunterladen Inhalt Inhalt Diese Seite drucken

Becker BOM 850C-II Handbuch Seite 44

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Installation
Menu 7:
Adjust the light phases
1. Select menu item "7".
After approximately 2 seconds, the display fl ashes and the set value for light time appears.
The factory setting is "0".
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) buttons.
Menu value
0
1
2
3
4
5
6
7
8
9
Remarks:
- TAM (Door open message): 24 volts at door not closed.
- If a warning time is set, the light and 24V will switch on before the drive starts up.
3. Press the programming button (PROG button) (D).
The number "8" is displayed.
Menu 8:
Door adjustments
1. Select menu item "8".
After approximately 2 seconds, the display fl ashes and the set value time appears.
The factory setting is "4".
For optimal movement and to maintain the forces, the corresponding door type must be selected.
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) buttons.
Menu value
0
1
2
3
4
5
6
7
8
9
3. Press the programming button (D).
The number "9" is displayed.
44
Light time
60 s
120 s
240 s
0 s
0 s
60 s
120 s
60 s
120 s
240 s
Double swing gate
Non-swinging door, Canopy
Swing door, tilting door, normal
Swing door, tilting door, sensitive running
Universal setting (factory)
Sectional door with tension spring fi tting (Topspeed)
Sectional door with torsion spring fi tting (Topspeed)
Industrial door with standard fi ttings
Side section door (Topspeed)
Side section door with secondary closing edge
Warning time
0 s
0 s
0 s
0 s
3 s
3 s
3 s
0 s
0 s
0 s
Door type
24 V
60 s
120 s
240 s
0 s
0 s
0 s
0 s
TAM
TAM
TAM

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis