Verfügbare Sprachen

LED
Green
Orange
Red (2)
(1)
(3)
*) If the error re-occurs, contact customer service
Acknowledge alarm
If a condition arises that triggers an alarm, this will be indi-
cated through the illumination of the alarm LED (2) and, if
applicable, one of the other LEDs. After rectifying the cause
of the alarm, the alarm can be acknowledged by pressing the
button (7).
016-102_01 DE_EN_FR
Acoustic
signal
Orange
(interval)
(4) / (5)
-
Pumping station / Installation and operating manual
Description
Alarm level exceeded
Maximum switch-
ing cycles exceeded
Switching off the alarm tone
Press button (7) 1x
Acknowledge alarm
Press and hold button (7) > 3 seconds.
✓ The alarm indicator goes out, the alarm is acknowledged.
Measure
Wait until the level drops
below the alarm level again
Acknowledge alarm
and replace control unit
87 / 148