Trouble shooting

Problem
Possible cause
No mains power supply
Worn out carbon brushes
Appliance
Motor faulty
won't start
On/Off switch (
The suction tubes (
ection bag (
tubes (
(
Internal loose contact
Intermittent
Power cable damaged
operation
On/Off switch (
Collection bag (
Weak or
no suction
Collection bag (
power/
Impeller, blower or suction pipe
throughput
(
Impeller does
Foreign body blocking the impel-
ler
not move
4) defective
16) and coll-
14), and/or blower
9) and protective cover
7) are not correctly mounted.
4) defective
14) is full
14) is dirty
9/16) is clogged or blocked
Corrective action
Check the socket, cable, line, plug and
fuse and have them repaired by a qua-
lified electrician if necessary.
Send in to Service Centre for repair
See the section on „Initial start-up"
Send in to Service Centre for repair
Empty collection bag
Clean collection bag
see „Removal of clogging
and blockage"
Remove the blockage (see „Removal
of clogging and blockage")