Herunterladen Inhalt Inhalt Diese Seite drucken

Commissioning; Connecting Power - Siemens SITRANS F FUS1020 IP65 NEMA 4 Schnellstart

Durchflussmessgeräte
Vorschau ausblenden Andere Handbücher für SITRANS F FUS1020 IP65 NEMA 4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Commissioning

Connecting Power

Turn off main power before installing AC connections to the flowmeter. Contact with
exposed wiring may lead to fire, electric shock, or serious personal injury.
1. Using a cross-head screwdriver, remove the six #8 securing screws from the Keypad
2. Loosen the captive setscrew securing the Power Input/Fuse Cover and remove cover.
3. To determine type of power connection refer to the following part numbers: 1020N-S =
4. Pull either the AC or DC wires through flowmeter case cable hole.
5. Locate power plug P1. Loosen P1 connector screws.
6. Wire input AC or DC power wires to the appropriate screws and tighten screws securely.
Disable power before servicing fuse F1.
SITRANS FUS1020 IP65 NEMA 4 Quick Start
Operating Instructions (Compact), 4/2009, CQO:QSG006 Revision B
WARNING
Enclosure Cover and remove cover.
AC Power or 1020N-Z = DC Power
Note
Power Supply connector wires should be stripped stranded or solid conductors AWG 12 -
18.
P1 Terminal #
1
2
3
CAUTION
AC
HOT
NEU
GND
3
DC
+
-
GND
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis