This equipment should be mounted at the well ventilated places and as per the re-
gulations in force. The installation personnel should consider the laws and norms
applicable to the release of burnt gases and ventilation.
• Your hob is designed to be installed on the standard counters which you may
find in the market.
• The materials used on the surface and the connections under the counter should
be resistant against minimum 100°C temperature.
• A safe distance should be left between the hob and the counter walls (Figure 4).
• The hole to be provided for the hob on the counter should be as per the figure.
(Figure 4)
• The distance between the hob bottom and any surfaces beneath should be at least
25 mm. (Figure 5)
• The distance between the cook top ad another
device (e.g.kitchen hood) shall not be less than
700mm (Figure 5).
• If 60 cm Hobs will be place on a built in oven
without any cooling system, it is recommended
to leave 300 cm² of ventilation hole in order to
ensure air circulation. If 75 or 90 cm hob will be
placed, the oven has to have a cooling fan.